Our state-of-the-art chemical testing laboratory offers a wide range of services for building materials, water, agricultural soil, and food testing. We use the latest equipment and methods to ensure accurate and reliable results. Our team of experienced chemists is dedicated to providing our clients with the highest quality of service.

We perform chemical tests to get an overall understanding of the material used and its compliance with the required standard. We highly promote testing the chemical parameters of building materials as it is crucial in quality control.

Cement | Concrete | Steel | Soil | Fly Ash | Coarse & Fine aggregate | Admixture | Construction Water

Career Illustration
Cement
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Chemical test of Cement includes Silica, Ferric Oxide, Alumina , Calcium Oxide, Magnesium Oxide, Sulphuric Anhydride, Insoluble Residue, Chloride 4 Days 1 kg IS 4032 : 1985 (Amendment No.2 )
Steel
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Carbon 3 Days 1 Bar (300 cm) Each IS 228 (Part-1) :1987 RA:2018
2 Sulpher 3 Days 1 Bar (300 cm) Each IS 228 (Part-9) :1987 RA:2019
3 Phosphorus 3 Days 1 Bar (300 cm) Each IS 228 (Part-3) :1987 RA:2018
4 Manganese 3 Days 1 Bar (300 cm) Each IS 228 (Part-2) :1987 RA:2018
Fly Ash
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Chemical test of Fly Ash includes 8 tests mandatory 5 Days 1 Kg IS-1727(Clause 5.10): 1967
Coarse aggregate
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Soundness Test 5 Days 20 Kg IS 2386(Part-5):1963 RA: 2016
2 Alkali Reactivity 7 Days 5 Kg IS 2386(Part-7):1963 RA: 2016
3 Deleterious Material 1 Day 6 Kg IS 2386(Part-2):1963 RA: 2016
Fine Aggregate
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Soundness Test 5 Days 20 Kg IS 2386(Part-5):1963 RA: 2016
2 Alkali Reactivity 7 Days 5 Kg IS 2386(Part-7):1963 RA: 2016
3 % of Deleterious Material 1 Day 10 Kg IS 2386(Part-2):1963 RA: 2016
Admixture
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Dry Material Content (Liquid Or Non-Liquid) 3 Days 10 Nos. IS 3495(Part-1):1992 RA:2019
2 Water Absorption 3 Days 10 Nos. IS 1077:1992 RA: 2016
3 Elongation Index 2 Days 10 Nos. IS 3495 (Part-3):2019
4 Flakiness Index 1 Day 10 Nos. IS 3495(Part-2):1992 RA:2019
Construction Water
Sr.No Name of Test Minimum Period required for testing Minimum Sample required for One Test Test Method / Specification
1 Chemical test of Construction Water includes 8 tests 2 Days 10 Kg IS 3025:1983 RA: 2019
2 Chemical test of Drinking Water We can provide up to 35 tests 3 Days 2 Liter IS 3025:1983 RA: 2019