Our state-of-the-art chemical testing laboratory offers a wide range of services for building materials, water, agricultural soil, and food testing. We use the latest equipment and methods to ensure accurate and reliable results. Our team of experienced chemists is dedicated to providing our clients with the highest quality of service.
We perform chemical tests to get an overall understanding of the material used and its compliance with the required standard. We highly promote testing the chemical parameters of building materials as it is crucial in quality control.
Cement | Concrete | Steel | Soil | Fly Ash | Coarse & Fine aggregate | Admixture | Construction Water
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Chemical test of Cement includes Silica, Ferric Oxide, Alumina , Calcium Oxide, Magnesium Oxide, Sulphuric Anhydride, Insoluble Residue, Chloride | 4 Days | 1 kg | IS 4032 : 1985 (Amendment No.2 ) |
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Carbon | 3 Days | 1 Bar (300 cm) Each | IS 228 (Part-1) :1987 RA:2018 |
| 2 | Sulpher | 3 Days | 1 Bar (300 cm) Each | IS 228 (Part-9) :1987 RA:2019 |
| 3 | Phosphorus | 3 Days | 1 Bar (300 cm) Each | IS 228 (Part-3) :1987 RA:2018 |
| 4 | Manganese | 3 Days | 1 Bar (300 cm) Each | IS 228 (Part-2) :1987 RA:2018 |
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Chemical test of Fly Ash includes 8 tests mandatory | 5 Days | 1 Kg | IS-1727(Clause 5.10): 1967 |
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Soundness Test | 5 Days | 20 Kg | IS 2386(Part-5):1963 RA: 2016 |
| 2 | Alkali Reactivity | 7 Days | 5 Kg | IS 2386(Part-7):1963 RA: 2016 |
| 3 | Deleterious Material | 1 Day | 6 Kg | IS 2386(Part-2):1963 RA: 2016 |
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Soundness Test | 5 Days | 20 Kg | IS 2386(Part-5):1963 RA: 2016 |
| 2 | Alkali Reactivity | 7 Days | 5 Kg | IS 2386(Part-7):1963 RA: 2016 |
| 3 | % of Deleterious Material | 1 Day | 10 Kg | IS 2386(Part-2):1963 RA: 2016 |
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Dry Material Content (Liquid Or Non-Liquid) | 3 Days | 10 Nos. | IS 3495(Part-1):1992 RA:2019 |
| 2 | Water Absorption | 3 Days | 10 Nos. | IS 1077:1992 RA: 2016 |
| 3 | Elongation Index | 2 Days | 10 Nos. | IS 3495 (Part-3):2019 |
| 4 | Flakiness Index | 1 Day | 10 Nos. | IS 3495(Part-2):1992 RA:2019 |
| Sr.No | Name of Test | Minimum Period required for testing | Minimum Sample required for One Test | Test Method / Specification |
|---|---|---|---|---|
| 1 | Chemical test of Construction Water includes 8 tests | 2 Days | 10 Kg | IS 3025:1983 RA: 2019 |
| 2 | Chemical test of Drinking Water We can provide up to 35 tests | 3 Days | 2 Liter | IS 3025:1983 RA: 2019 |